The monitor configuration used to present patient observations.
- Optional; omitted values remain unspecified.
Patient
Rhythm vocabulary and an associated recording.
Distinguish rhythm, ECG findings, acquisition settings, and a recording.
Scenario standard · Execution capabilities
object
Optional; omitted means unspecified
Connected channels expose available measurements without changing physiology. An explicit empty patient connection map starts disconnected. Omitted event channels inherit their preceding connection. Omitting the patient connection map makes available channels connected.
object
Optional; omitted means unspecified
Connect or disconnect an equipment channel when this resource response is released.
"ecg" | "bloodPressure" | "spo2" | "respiration" | "temperature" | "capnography" | "arterialPressure"
Optional; omitted means unspecified
Select one of the declared channel alternatives; use the fields belonging to that alternative.
object
Optional; omitted means unspecified
Acquisition context plus independent rhythm and morphology findings; all supplied scale numbers must be positive.
string
Required
ECG image, signal, or video manifest entry with an accessible description.
Shared format conventions · All format elements · Download specification
The monitor configuration used to present patient observations.
The ECG rhythm displayed on the monitor. Select the rhythm separately from whether the patient has a palpable pulse.
Allowed values
Whether a palpable pulse is present. Use this to distinguish perfusing and pulseless presentations of the displayed rhythm.
Connected channels expose available measurements without changing physiology. An explicit empty patient connection map starts disconnected. Omitted event channels inherit their preceding connection. Omitting the patient connection map makes available channels connected.
ECG: connected exposes the available measurement; disconnected hides it without changing physiology.
Blood pressure cuff: connected exposes the available measurement; disconnected hides it without changing physiology.
Pulse oximetry: connected exposes the available measurement; disconnected hides it without changing physiology.
Respiratory monitoring: connected exposes the available measurement; disconnected hides it without changing physiology.
Temperature probe: connected exposes the available measurement; disconnected hides it without changing physiology.
Capnography: connected exposes the available measurement; disconnected hides it without changing physiology.
Arterial pressure: connected exposes the available measurement; disconnected hides it without changing physiology.